Lithium Battery Pack Calculator

Lithium Battery Pack Calculator

Lithium-ion Battery Pack Calculator

From cell count to runtime in one place, with an engineer’s reply within 24 hours.

Choosing a pack is easier with the numbers in front of you. Lay out the cells, test your load, then pass the figures to our engineers so the first reply already fits your project.

Whether you need a fully custom pack, a standard design, or a second opinion on a quote you already hold, we work from your figures and suggest a practical route.

  • Compare series and parallel layouts before you commit
  • See runtime against a realistic duty cycle
  • Send one summary instead of retyping specs

Worked examples and tips: Lithium Battery Calculator Guidance

Series/Parallel Battery Pack Builder

Pick a cell, choose how many go in series and in parallel, and read off the pack’s rated voltage, capacity and energy.

A typical voltage is filled in when you pick a chemistry. Replace it with the figure on your cell’s datasheet.

More cell specs (optional)

These only add a voltage range, a weight and a current line to the result. The current line ignores the BMS, wiring, heat and connectors.

Pack result

3S2P

Some inputs need fixing (marked above). Results return once they are corrected.

Total cells

–

Rated voltage

–

Rated capacity

–

Stored energy

–

Pack voltage rangeAdd in cell specs
Weight of the cells aloneAdd in cell specs
Current from the cells aloneAdd in cell specs

–

A planning figure, not an approved design. Discharge limits, usable energy, charger match and shipping class still need an engineer’s check.

Battery Pack Runtime Estimator

Enter what your device draws to see how long the pack lasts, or enter the hours you need to see how big the pack must be.

The 80 % and 90 % shown are starting guesses. Replace them with figures from your cell data and your converter. Efficiency only applies when the load is given in watts.

Runtime result

The pack builder has inputs that need fixing. Correct them, or untick “Use the pack from the builder” and type the pack voltage and amp-hours here.

Some inputs need fixing (marked above). Results return once they are corrected.

Runtime

–

In hours

–

Usable energy

–

Energy needed

–

Capacity needed

–

Parallel cells needed

–

Share of rated energy you can actually use

Average load–
Average draw from the pack–
Average current–
Discharge rate–
Draw vs the cells’ current rating–

A planning figure only. Nothing here allows for cold, ageing, load peaks or high-rate losses, so check it against cell test data.

Send the Numbers to Our Engineers

Both results travel with your enquiry automatically, so there is nothing to copy or retype. This is exactly what we will receive:

Your details





    Thank you, your enquiry is on its way

    Your details and calculator figures have reached our sales team. An engineer will reply to you within 24 hours.

    How Each Figure is Worked Out

    FigureHow it is worked outKeep in mind
    Total cellsS × PTreats every cell as identical.
    Rated voltageS × voltage per cellReal voltage rises and falls with charge level and load.
    Rated capacityP × capacity per cellA label value, not a measured one.
    Stored energyRated voltage × rated capacityBefore temperature, ageing and conversion losses.
    Average loadRunning load × share of time running + idle load × the remainderShort peaks are smoothed into one average.
    Pack drawLoad ÷ efficiency (watts), or amps × pack voltage (amps)A single efficiency figure stands in for a whole curve.
    RuntimeStored energy × usable share ÷ pack drawNo correction for cold, age or high discharge rate.
    Energy neededPack draw × hours needed ÷ usable shareAdd your own safety margin on top.

    Things to Check Before You Finalize a Design

    Voltage window

    Compare full-charge and cut-off voltage with what your device accepts, not only the nominal figure.

    Current and protection

    Note continuous, start-up and peak current, then size the BMS, wiring and connectors as one system.

    Temperature

    Charging and discharging have separate temperature limits, and neither tool corrects for heat or cold.

    Cell type

    Lithium-ion and sodium-ion cells differ in voltage, energy density and low-temperature behavior, so confirm the cell suits your use.

    FAQs about Lithium-ion Battery Pack Calculator

    Can I use this calculator for LiFePO4 or sodium-ion cells?

    Yes. The arithmetic is the same for any chemistry, but you must enter the nominal voltage from your cell datasheet. Choosing a chemistry fills in a typical value as a starting point only.

    Does the estimate cover cold or hot conditions?

    No. Neither calculator applies a temperature factor. Available capacity changes with temperature, load and ageing, so include your operating temperature range when you contact our engineers.

    How do I calculate battery pack voltage, capacity and energy?

    Pack nominal voltage is the number of cells in series times the cell nominal voltage. Pack capacity is the number of cells in parallel times the cell capacity in Ah. Nominal energy in Wh is pack voltage times pack capacity. For example, a 10S4P pack of 3.6 V 5 Ah cells gives 36 V, 20 Ah and 720 Wh.

    What usable capacity and efficiency should I enter?

    The defaults of 80 percent usable capacity and 90 percent efficiency are planning placeholders, not datasheet values. Use the discharge cut-off and rate data for your cell, and the efficiency of your converter or motor driver at your real load. If you enter the load as current at the battery terminals, efficiency is already included.

    What does 3S2P mean in a battery pack?

    3S2P means three cells in series and two in parallel, so six cells in total. Series groups add voltage and parallel groups add capacity. The label alone does not define a full battery specification, because cell model, chemistry, protection and interface still have to be chosen.

    Does the Wh figure decide shipping eligibility?

    No. Transport classification also depends on chemistry, test reports, packaging, quantity and state of charge.

    Can I choose a BMS from these numbers?

    Not on their own. BMS selection depends on the true load profile, protection timing, wiring and heat dissipation.

    How quickly will CMB reply to my email?

    Our target is to respond with personalized battery pack suggestions within 24 hours of receiving your enquiry.

    How is battery runtime estimated?

    Runtime is the usable energy divided by the average power drawn from the pack. Usable energy is the nominal energy multiplied by the usable capacity percentage. When the load is entered as power at the device, conversion efficiency raises the power drawn from the pack. Duty cycle and standby load are blended into one average.

    Is a 10-cell NMC pack automatically a 36 V replacement?

    Not necessarily. Ten cells at 3.6 V give 36 V nominal, but the charge voltage, cut-off voltage and device limits must also match.

    How do I calculate battery runtime from voltage, Ah and load?

    First convert the pack rating to watt-hours by multiplying nominal voltage by capacity in amp-hours. Apply an evidence-based available-energy factor and reserve, then divide the resulting planning energy by the average power drawn from the battery. If the load value is measured on the device side, account for conversion losses.

    Does the estimated runtime guarantee that my battery pack will power the equipment?

    No. The estimate is an energy-planning result, not a battery design approval. Confirm the full voltage range, continuous and peak current, BMS protection settings, thermal conditions, connectors, wiring, charging requirements and end-of-life performance in the actual equipment.

    We Are Ready for Your Project

    Our experts with 18 years of battery experience can help you select the best battery for your application. We don’t just build battery packs — we engineer reliable power solutions backed by transparent manufacturing, certified quality, and a commitment to sustainability.

    Factory Transparency

    From raw material sourcing to final assembly, we offer full visibility into our manufacturing process. OEM/ODM clients benefit from detailed production updates, traceable quality controls, and real-time communication with our engineering and project teams.Read More »

    Our Sustainability Commitments

    We’re all about putting our core values into action, making our batteries more reliable and lasting, and weaving a more sustainable future for your high-tech devices and the planet.Read More »

    Complete Certifications

    We ensure all battery packs meet rigorous safety and performance standards. Certifications include:
    • UN38.3 for transport safety
    • IEC 62133 for international safety compliance
    • UL 2054 / UL 1642 for system and cell-level standardsRead More »

    Advanced Battery Technologies

    Our engineering team specializes in designing battery packs that perform under extreme conditions:
    •  Low & High Temperature Operation
    • Wide Temperature Range Compatibility
    • Smart Battery Management Systems (BMS)Read More »