A robot battery has to do more than keep a machine running. It must supply enough energy for the required operating time, handle motor startup and acceleration, fit inside the robot, and work with its controller, charger, and operating environment.
A battery that looks right on paper may shut down when a motor starts. Another may provide enough power but weigh too much, take up valuable space, or fail to meet the robot’s daily operating schedule.The usual cause is voltage sag. When a motor pulls a peak current, the pack voltage drops by current × pack resistance. If it falls below the controller’s low-voltage limit, the robot restarts even though the battery still has charge.
How to choose a battery for a robot? Start with the robot’s actual load profile, then check voltage, capacity, discharge current, chemistry, BMS, mechanical design, and operating conditions. These eight specifications will help you narrow down a suitable battery before requesting a quote or testing a prototype.

Quick Answer:What to Check When Choosing a Robot Battery
Before selecting a robot battery, check these eight specifications:
| Specification | What to Check |
| Voltage | Operating voltage range, fully charged voltage, and low-voltage limit |
| Capacity | Required runtime, average power consumption, and usable energy |
| Discharge current | Continuous current, peak current, and peak duration |
| Battery chemistry | Energy density, cycle life, safety requirements, and operating conditions |
| Operating environment | Temperature, water, dust, vibration, and impact |
| BMS | Protection functions, current capability, SOC reporting, and communication |
| Mechanical design | Dimensions, weight, mounting, connector, and thermal management |
| Certification | Applicable product, application, and transportation requirements |
A battery should meet all eight requirements, not just voltage and capacity. A pack with enough Ah may still fail if it cannot supply the required current or maintain a stable voltage during motor startup.
Key Takeaways
- Start with the robot’s load profile. Motor startup, acceleration, lifting, computing, sensors, and standby loads all affect battery selection.
- Size energy and current separately. Average power determines required energy and runtime; peak loads determine current capability and voltage stability.
- Choose chemistry based on the application. NMC and LiFePO4 have different tradeoffs in weight, energy, cycle life, and operating requirements.
- Check the complete battery system. BMS, connector, cables, charger, enclosure, and controller must work together.
- A standard battery may be enough. Choose a custom battery pack only when the standard options cannot meet your electrical, mechanical, communication, or environmental requirements.
Start With the Robot’s Load Profile Before Choosing Any Battery
The first step in robot battery selection is to understand how the robot actually consumes power during operation. A robot does not draw the same current all the time. Its load changes with movement, acceleration, payload, terrain, task, and idle periods.
For example, an AMR moving along a warehouse floor may draw relatively steady power while cruising. During startup, turning, ramp climbing, or carrying a heavier payload, its motors may demand much more current. At the same time, onboard computers, sensors, cameras, communication modules, and other electronics continue consuming power.
Before selecting a battery, list the main loads and when they operate.
| Robot Load | What to Consider |
| Drive motors | Startup, acceleration, turning, ramps, payload, and stall conditions |
| Lift or actuator | Lifting force, movement frequency, and peak current |
| Controller and computing | Continuous power consumption during operation |
| Sensors and cameras | LiDAR, cameras, depth sensors, and other devices |
| Communication | Wi-Fi, cellular, Bluetooth, and industrial communication modules |
| Standby | Idle time, sleep mode, and power consumption between tasks |
The most useful information is a measured current or power profile from a working prototype. If the robot is still under development, use motor, controller, and component specifications to estimate the load, but keep estimated values separate from measured values.
What Does a Robot’s Load Profile Look Like?
A robot battery must support both continuous operation and short periods of higher demand. The following is a simplified example of how power demand can change during a mission.
Do not size the battery from the motor’s rated power alone. Consider how many motors operate at the same time, how often peak loads occur, and how long the robot spends in each operating state.
Legged robots are an extreme case. In walking, every footstep pulls a current pulse several times the typical current and lasting only tens of milliseconds, and jumping or landing is higher still. To see this on your own robot, log battery voltage and current at about 1kHz during a real task. A one-second average hides the peaks.
Robot Battery Voltage and Capacity: How to Size the Battery Pack
Voltage and capacity determine the battery’s energy storage capability, but they must match the robot’s electrical system and operating time.
How to Choose the Right Battery Voltage
The battery’s voltage must stay within the operating range of the motor controller, DC-DC converters, and other powered devices throughout charging and discharging.
Check the following before selecting nominal voltage:
- Maximum battery voltage when fully charged
- Normal operating voltage range
- Minimum voltage the controller can accept
- Voltage drop during high-current operation
- Battery discharge cutoff voltage
- Charger output voltage
Two battery packs with the same nominal voltage may have different fully charged voltages and discharge characteristics. Confirm the complete voltage range before selecting the pack.
Chemistry changes the window too. A 13S NMC pack is 46.8V nominal and 54.6V fully charged, while a 13S LiFePO4 pack is only about 41.6V nominal. Check the full-charge voltage against the motor driver’s voltage rating.
How to Calculate Robot Battery Capacity
Battery capacity should be based on the robot’s average energy consumption and required runtime—not simply the sum of motor rated capacities.
Start with:
Required energy (Wh) = Average power consumption (W) × Required runtime (h)
Then account for usable battery capacity, system efficiency, reserve, and operating conditions.
Estimated nominal battery energy (Wh) = Required energy ÷ Usable energy fraction
Finally:
Battery capacity (Ah) = Nominal battery energy (Wh) ÷ Nominal voltage (V)
For example, if a robot consumes an average of 120W and needs to run for 5 hours:
- Required energy = 120W × 5h = 600Wh
- If the design uses 80% of nominal battery energy, the nominal energy target is 750Wh
- At a nominal battery voltage of 25.2V, the calculated capacity is approximately 29.8Ah
This is an initial sizing estimate, not a final battery specification. The actual usable energy depends on the battery, load, temperature, discharge rate, voltage limits, aging, and system losses.
Use a battery pack calculator to help estimate the required capacity and configuration, then verify the result against the robot’s actual load.
Robot Battery Discharge Current: Continuous, Peak and Internal Resistance
A robot battery must supply enough current without excessive voltage drop, heat, or protection shutdown. This is why continuous current and peak current need to be evaluated separately.
Continuous Discharge Current
Continuous discharge current is the current a battery can supply for an extended period under specified conditions.
Check the maximum current during normal operation, including situations such as:
- Repeated turning
- Climbing ramps
- Running multiple motors simultaneously
- Operating computing and auxiliary loads at the same time
The battery cells, BMS, busbars, wires, connectors, and fuse must all support the required current.
Peak Discharge Current
Peak current refers to a higher current demand over a limited period. It may occur during startup, acceleration, lifting, sudden changes in direction, or other high-load events.
When evaluating peak current, ask the supplier:
- How much peak current can the battery deliver?
- How long can it sustain that current?
- How frequently can the peak occur?
- At what state of charge and temperature?
- What voltage drop occurs during the event?
- Will the BMS disconnect during the pulse?
A peak current rating without a duration is incomplete for engineering selection. A 100A pulse lasting 100ms is very different from 100A lasting several seconds.
Why Internal Resistance Matters
Internal resistance affects voltage drop and heat generation when current flows.
A simplified voltage-drop estimate is:
Voltage drop (V) = Current (A) × Resistance (Ω)
For example, at 60A with a total effective resistance of 0.03Ω:
60A × 0.03Ω = 1.8V voltage drop
This drop may cause the motor controller or other electronics to reach their low-voltage limit, even if the battery still has remaining capacity.
Pack resistance covers more than the cells: series count × cell resistance ÷ parallel count, plus connectors, harness, and BMS. It also rises in the cold and with age. For example, a 13S4P pack of 18mΩ cells has 13 × 18 ÷ 4 = 58.5mΩ, so 100A drops the voltage by 5.85V. A cell that reads 18mΩ at room temperature may read about 45mΩ at 0°C.
Heat generation also increases with current:
Heat loss (W) = Current² × Resistance
For the same example, 60A × 60A × 0.03Ω = 108W of heat.
For a load that changes over time, calculate heat with RMS current, not average current.
Note that the internal impedance on a datasheet is usually an initial value measured with AC at 1kHz. It is a quality-control reference, not the DC resistance under load. For selection, ask the supplier for pulse-discharge voltage drop at your current, temperature, and state of charge.
What Is a Good C-Rate for a Robot Battery?
C-rate expresses discharge current relative to battery capacity. For a 20Ah battery:
| Discharge Rate | Current |
| 0.2C | 4A |
| 0.5C | 10A |
| 1C | 20A |
| 2C | 40A |
| 5C | 100A |
A higher C-rate does not automatically mean a better battery for a robot. Check the cell datasheet, pack configuration, BMS rating, temperature rise, voltage drop, and peak duration.
Do not compare suppliers using C-rate alone. Ask how the current rating was established and whether it applies to the complete battery pack or only the cells.
Read more about the role of C-rate in lithium-ion battery pack design.
Robot Battery Chemistry: Lithium-Ion vs LiFePO4
The right battery chemistry depends on how the robot operates. Weight, available space, energy demand, cycle frequency, safety requirements, and temperature conditions all influence the choice. As a rule of thumb, choose NMC when weight and installation space are the main limits, and choose LiFePO4 when cycle life and daily cycling matter more than weight.

Two common rechargeable lithium battery options for robots are NMC lithium-ion and LiFePO4.
| Factor | NMC Lithium-Ion | LiFePO4 |
| Energy density | Generally higher | Generally lower |
| Weight and size | Useful when weight or space is limited | May require more space for the same energy |
| Cycle life | Depends on cell and operating conditions | Often well suited to frequent cycling |
| Nominal cell voltage | Typically 3.6–3.7V | Typically 3.2V |
| Cycle life in CMB projects | ≥1000 cycles at ≥80% retention (25.2V 50Ah, Case 4) | ≥2000 cycles at ≥70% retention (25.6V 120Ah, Case 3) |
When to Consider NMC
NMC may be a suitable choice when:
- Battery weight is a major constraint
- The robot has limited installation space
- Longer runtime is needed without increasing pack size significantly
- The application requires a balance of energy and power capability
When to Consider LiFePO4
LiFePO4 may be a suitable choice when:
- The robot operates through frequent charge and discharge cycles
- Long cycle life is a priority
- Pack weight and volume have more flexibility
- The application benefits from the chemistry’s thermal and operating characteristics
There is no single best chemistry for every robot. The final choice should be based on the operating requirements and validated battery design.
Robot Battery Environment: Temperature, Waterproofing and Vibration

A robot battery must operate under the environmental conditions the machine will actually encounter. Temperature, water, dust, vibration, and mechanical impact can all affect battery performance, safety, and service life.
Operating and Charging Temperature
Battery performance changes with temperature.Low temperatures can reduce available capacity and increase internal resistance. Charging lithium batteries below their permitted temperature range can cause cell damage and safety risks.
Confirm:
- Minimum discharge temperature
- Maximum discharge temperature
- Minimum and maximum charging temperature
- Whether low-temperature charging is required
- Whether heating or temperature control is needed
- Expected temperature inside the battery enclosure
The charging temperature range may be different from the discharge temperature range. Make sure both are specified. As a rule of thumb, available capacity falls about 15–25% near 0°C and about 40% at−10°C. A rated discharge temperature is where the battery pack may be used, not where it delivers its rated capacity.
Waterproofing and Dust Protection
If the robot works outdoors, on farms, in cleaning environments, or around water, the enclosure and sealing design need to match the actual exposure.
The IP rating should be selected according to the robot’s operating environment. IP67 and IP68 are not interchangeable guarantees for unlimited water exposure. IP68 immersion depth and duration depend on the applicable test conditions and agreement.
Vibration and Mechanical Impact
Robots can experience repeated vibration, movement, shock, and changes in load. Battery design should consider:
- Cell fixation and internal structural support
- Weld and electrical connection integrity
- Enclosure strength
- Mounting points
- Cable and connector retention
- Protection against movement inside the battery pack
For more information, see CM Batteries’ reliability testing process.
Robot BMS and Communication
The Battery Management System (BMS) monitors the battery and provides protection against operating conditions that could damage the cells or create safety risks. For robots, a smart BMS may also communicate with the robot controller to support battery monitoring and operating decisions.
What BMS Functions Does a Robot Battery Need?
Depending on the battery design, the BMS may include:
- Overcharge protection
- Over-discharge protection
- Over-current protection
- Short-circuit protection
- Temperature monitoring and protection
- Cell balancing
- State of Charge (SOC) reporting
- Battery fault reporting
A single fixed low-voltage cutoff often fails on robots. It either trips during a harmless current peak, or lets the cells go too low at rest. Ask for a tiered approach: a warning, then a reduced allowed discharge current, then cut-off. The BMS should report the allowed discharge current to the controller.
Battery Communication Protocols
If the robot controller needs battery information, communication must be defined early in the design process.
| Communication | Typical Use |
| CAN | Communication between the battery and robot control system |
| RS485 | Battery monitoring and communication with industrial controllers |
| UART | Serial communication with embedded control systems |
| Bluetooth | Wireless monitoring, configuration, or diagnostics where supported |
Selecting a communication interface is not enough. Confirm the protocol, baud rate, message definitions, data fields, command requirements, and compatibility with the robot controller.
Useful fields to request: SOC, state of health, minimum and maximum cell voltage, maximum temperature, allowed charge and discharge current, and protection flags. Agree in writing whether current is signed, its scale, and the byte order. A signed/unsigned mix-up can show a small negative current as about 6500A.
Robot Battery Form Factor, Connectors and Thermal Design
The battery must fit the robot mechanically and electrically. A battery that meets the voltage, capacity, and current requirements may still be unsuitable if it interferes with the chassis, increases the center of gravity, or cannot be connected and serviced properly.
Battery Dimensions and Weight
Confirm the available battery bay and installation method before finalizing the pack.
Important mechanical requirements include:
- Maximum length, width, and height
- Total battery weight
- Mounting points
- Removal and replacement method
- Battery position and center of gravity
- Space for cables, connectors, and maintenance
For mobile robots, battery placement can affect stability, traction, handling, and payload capacity.
Connector Selection
The connector must handle the expected current and fit the robot’s electrical and mechanical interface.
Consider:
- Continuous and peak current
- Contact resistance and temperature rise
- Voltage rating
- Polarity and keying
- Mating cycles
- Cable size and flexibility
- Ease of replacement and maintenance
The connector should not be selected by current rating alone. Its installation, contact quality, cable routing, and operating conditions matter.
See our guide to battery connector types.
Thermal Management
Heat may come from the cells, BMS, electrical connections, and the surrounding robot system. During high-current operation, resistive losses can raise battery temperature. In a compact robot, heat from motors, controllers, and computing components may also affect the battery.
A thermal solution that works in an open test setup may not perform the same way inside a sealed robot chassis.
In a sealed IP67 pack with no fan, heat leaves only by conduction: from the cells through thermal pads to the enclosure, then to the chassis. Check each link, because the weakest one sets the temperature.
For a deeper look at heat sources, cooling methods, and validation steps, see our guide to robot battery thermal management.
Robot Battery Certification and Transport Compliance
Battery certification and transport documentation depend on the product, target market, application, and project requirements. Before requesting a battery quote, identify the standards and documents needed for the finished battery pack and the equipment it powers.
| Standard / Document | What It Covers |
| UN 38.3 | Lithium battery transport testing |
| UN 38.3 Test Summary | Summary of applicable transport test information |
| SDS / MSDS | Safety information for the battery product |
| UL standards | Applicable product safety requirements, depending on battery and application |
| IEC standards | Applicable electrical and battery safety requirements, depending on product |
| CE | Applicable European conformity requirements for the finished product and its intended use |
| RoHS | Restrictions on specified hazardous substances, where applicable |
| ISO 9001 | Quality management system certification for the organization; not battery product certification |
Not every battery pack automatically holds every certification. Some requirements may be addressed through the customer’s finished equipment, while others may require battery-specific testing, documentation, or project support.
At CM Batteries, UL, IEC, CE and RoHS requirements are handled project by project. When a custom battery pack project requires them, we carry out the certification for that specific pack, and the resulting certificate or report applies to that battery pack design.
For transport, UN 38.3 documentation is particularly important. Confirm that the documentation corresponds to the battery being shipped.
CM Batteries can review the target application, destination market, and project certification requirements during battery design and quotation.
Four Robot Battery Selection Examples From CM Batteries Projects
The following projects illustrate how robot battery requirements can lead to different voltage platforms, capacities, chemistries, discharge ratings, and enclosure designs.
These examples are based on actual project specifications. They are not universal recommendations for every robot in the same category.
Case 1: 36V 20Ah 21700 Battery Pack for a Robot
A robot requiring high discharge current needs more than a battery with sufficient capacity. The pack must support the load while managing heat and maintaining stable voltage.
Project specifications
| Parameter | Specification |
| Nominal voltage | 36V |
| Capacity | 20Ah |
| Configuration | 10S4P |
| Cell type | 21700 |
| Max. discharge current | 80A |
| Burst discharge current | 140±10A, ≤30ms |
| Enclosure | Aluminum housing |
| Energy | 720Wh |
| Cycle life | ≥400 cycles at ≥60% capacity retention |
| Weight | Approx. 5kg |
| Max. discharge rate | 4C (80A ÷ 20Ah) |
The aluminum housing is part of the pack’s thermal design and can help transfer heat. Its effectiveness depends on the internal construction, contact surfaces, heat generation, and operating conditions.
View the 36V 20Ah 21700 robot battery project

Case 2: 43.2V 20Ah High-Power Robotics Battery Pack
This battery pack is designed for robotics applications requiring a compact battery with high discharge capability.
Project specifications
| Parameter | Specification |
| Nominal voltage | 43.2V |
| Capacity | 20Ah |
| Energy | 864Wh |
| Cell type | 21700 |
| Max. discharge current | 100A |
| Burst discharge | 320A, ≤5ms |
| Weight | Approx. 3.45kg |
| Cycle life | ≥400 cycles at ≥70% capacity retention |
| Max. discharge rate | 5C (100A ÷ 20Ah) |
The 320A burst rating is specified for a duration of up to 5ms. This is a very short pulse and should not be treated as a motor-start current rating for longer startup events. Actual robot current waveforms and peak duration must be evaluated before battery selection.
View the 43.2V 20Ah 21700 robotics battery project

Case 3: 25.6V 120Ah IP67 LiFePO4 Battery for Agricultural Robots
Agricultural robots may operate outdoors, where battery capacity, environmental protection, communication, and cycle life all matter.
Project specifications
| Parameter | Specification |
| Nominal voltage | 25.6V |
| Capacity | 120Ah |
| Chemistry | LiFePO4 |
| Max. discharge current | 50A |
| Burst discharge | 80A, ≤1000ms |
| Cycle life | ≥2000 cycles at ≥70% capacity retention |
| Weight | Approx. 24.5kg |
| Protection rating | IP67 |
| Communication | RS485 |
| Cell supplier | EVE |
| Max. discharge rate | 0.4C (50A ÷ 120Ah) |
The battery uses a waterproof enclosure design for the project’s outdoor operating requirements. IP67 protection is rated for temporary immersion, tested at up to 1m for 30 minutes under the IP code test conditions.
View the 25.6V 120Ah IP67 battery project

Case 4: 25.2V 50Ah 21700 Battery Pack for AGV / Robot
This project uses NMC lithium-ion cells to balance capacity, weight, and operating requirements in an AGV or robot application.
Project specifications
| Parameter | Specification |
| Nominal voltage | 25.2V |
| Capacity | 50Ah |
| Configuration | 7S10P |
| Cell type | 21700 / 50E |
| Chemistry | NMC |
| Max. discharge current | 20A |
| Burst discharge | 100±10A, ≤100ms |
| Cycle life | ≥1000 cycles at ≥80% capacity retention |
| Weight | Approx. 6.7kg |
| Communication | RS485 |
| Max. discharge rate | 0.4C (20A ÷ 50Ah) |
The battery pack is designed around the required 25.2V platform, capacity, communication interface, and burst discharge specification. The 100A peak rating is defined for up to 100ms, so the application load should be checked against that duration and the pack’s actual voltage behavior.
View the 25.2V 50Ah 21700 battery project

Custom Robot Battery Pack or Off-the-Shelf?
Not every robot needs a custom battery pack. If a standard battery already meets the voltage, capacity, discharge current, communication, dimensions, connector, charging, and certification requirements, it may be the simpler and more cost-effective option.
A custom battery pack becomes worth considering when the standard options cannot meet one or more important requirements.
| Requirement | Standard Battery | Custom Battery Pack |
| Voltage and capacity | Fixed options | Designed around project requirements |
| Dimensions | Standard enclosure | Customized battery bay fit |
| Discharge current | Defined rating | Configurable to required load |
| BMS communication | Available options | Selected protocol and data requirements |
| Connector | Standard interface | Selected for robot interface |
| Environment | Limited options | Enclosure and protection design for application |
| Certification | Existing documentation | Project-specific review and validation |
| Development | Faster if compatible | Requires design and sample validation |
When Does Customization Make Sense?
Consider a custom pack if your robot has:
- A restricted battery compartment
- High startup or peak current requirements
- A specific communication protocol
- Special charging or docking requirements
- Outdoor, waterproof, low-temperature, or high-temperature operating conditions
- Specific safety, certification, or transport documentation requirements
Robot Battery RFQ Checklist
A clear RFQ helps the battery manufacturer evaluate your requirements and reduces unnecessary back-and-forth during the initial design stage.
You do not need a complete battery design before contacting a supplier. Send what you have available, and identify the information that still needs to be confirmed.
- Robot Application: Robot type, operating scenario, payload
- Voltage: Nominal voltage and acceptable voltage range
- Capacity / Runtime: Required runtime or energy consumption
- Continuous Current: Normal operating current or power
- Peak Current: Peak magnitude, duration, and frequency
- Battery Chemistry: Preferred chemistry, if any
- Dimensions: Maximum battery size and available space
- Weight: Maximum allowable battery weight
- BMS: Protection requirements and communication protocol
- Connector: Connector model or electrical/mechanical requirements
- Environment: Temperature, water, dust, vibration, and impact
- Certification: Target market, required standards, and transport documents
- Charging: Charger voltage/current, charging window, docking or swap strategy
- Project Details: Prototype quantity, forecast volume, target timeline
- Controller Undervoltage Limit: Lowest voltage the motor driver and controller accept
- Low-temperature Operation: Lowest operating temperature, and whether charging below 0°C is needed
You can also send your robot drawings, battery compartment photos, existing battery specifications, controller datasheet, or measured load data.
Frequently Asked Questions About Robot Battery Selection
How Many Amps Does My Robot Battery Need?
The required current depends on the robot’s operating load. Calculate the continuous current for normal operation and identify peak current during startup, acceleration, lifting, or other high-load events. Specify the peak duration and frequency as well. The battery cells, BMS, connectors, cables, and protection components must support the complete load.
Why Does My Robot Restart When the Battery Still Has Charge?
Check the voltage trace. If it dips at a load step and recovers, the cause is usually voltage sag reaching the controller’s low-voltage limit, so lower the pack resistance or the limit. If it steps down and stays down, a protection has probably tripped, so read the BMS fault log. If it barely dips and the robot still restarts, look at the motor driver, power module, or grounding.
Should a Robot Use LiFePO4 or Lithium-Ion?
LiFePO4 is often considered for applications that prioritize cycle life and frequent operation. NMC lithium-ion is often considered when weight and energy density are important. Compare the complete battery pack, including operating conditions, current requirements, weight, volume, and lifecycle needs.
Can I Use a Drone Battery in a Robot?
A drone battery may be suitable for some robots, but compatibility must be checked. Confirm voltage, capacity, continuous and peak discharge current, connector, BMS, charging requirements, physical dimensions, and safety requirements. A battery designed for a drone is not automatically suitable for a ground robot.
How Long Will a Robot Battery Last on One Charge?
Runtime depends on usable battery energy and the robot’s average power consumption.
A basic estimate is:
Runtime (h) = Usable battery energy (Wh) ÷ Average power consumption (W)
Actual runtime will vary with payload, route, speed, acceleration, surface, temperature, battery aging, and auxiliary loads. A runtime estimate should be validated under representative operating conditions.
Do I Need CAN or RS485 on a Robot Battery?
Use the interface your robot controller already supports. Both CAN and RS485 are differential buses that can connect several devices. RS485 defines only the electrical interface, so the data format must be agreed with the supplier, while CAN is a message-based protocol widely used in vehicles and mobile platforms. In either case, confirm the protocol, baud rate, and data fields before ordering.
Can I Connect Two Robot Batteries in Parallel?
Only if the battery is designed for parallel use. The packs must have the same chemistry and voltage and a similar state of charge before they are connected, and the BMS, fuses, and connectors must handle both the combined load current and the equalizing current. Confirm this with the supplier before connecting packs in parallel.
Need a Battery Designed Around Your Robot?
Choosing a robot battery is about matching the pack to the robot’s electrical load, operating time, mechanical space, charging strategy, and working environment.
CM Batteries designs and manufactures custom rechargeable lithium battery packs for robotics, AGVs, AMRs, and other industrial equipment. From voltage and capacity selection to discharge capability, BMS communication, enclosure design, and project validation, we work with your requirements to develop a battery pack that fits your application.